Heat-Activated Automation:
Automatically deploys upon detecting heat or smoke, integrating with fire alarm systems for instant response.
SAFEGUARD YOUR FACILITY WITH HEAVY-DUTY FIRE & SECURITY SOLUTIONS
In industrial parks, fire outbreaks, unauthorized access, and extreme weather pose serious risks.
Our industrial-grade fireproof rolling shutters provide robust compartmentalization, helping contain fires, secure premises, and maintain operational continuity.
Key Benefits for Industrial Parks:
✔ High Fire Resistance (60/90/120 mins) –Certified to delay fire spread between units
✔ Durable & Weatherproof – Withstands harsh conditions (wind, dust, corrosion)
✔ Automated & Remote-Controlled – Smooth operation for high-traffic zones
✔ Forced-Entry Protection – Reinforced steel construction deters theft & vandalism
✔ Custom Sizes & Speeds – Tailored for warehouses, factories, and loading docks
Critical Applications:
- Warehouse Partitioning – Prevent fire from spreading across storage zones
- Manufacturing Facilities – Protect machinery & hazardous materials
- Logistics Centers – Secure loading bays while maintaining accessibility
- Power Plants & Chemical Storage – Extra protection for high-risk areas
Automatic Fire Roller Door Installation
Characteristics
SPACE-SAVING DESIGNS
FOLDABLE LIFT-TYPE VARIANTS (E.G., U-SHAPED, CURVED) FIT IRREGULAR OPENINGS WITHOUT SUPPORT COLUMNS, MAXIMIZING ARCHITECTURAL FLEXIBILITY.
LIGHTWEIGHT & STRUCTURAL EFFICIENCY
LOW WEIGHT (7 KG/M²): REDUCES BUILDING LOAD SIGNIFICANTLY, IDEAL FOR LARGE SPANS (E.G., ATRIUMS, SHOPPING MALLS) WHERE STRUCTURAL LOAD CAPACITY IS LIMITED.
SUPERIOR FIRE RESISTANCE
NO WATER PROTECTION NEEDED, UNLIKE TRADITIONAL STEEL SHUTTERS, INORGANIC COMPOSITE SHUTTERS ELIMINATE THE NEED FOR WATER SPRAY SYSTEMS, SAVING WATER AND REDUCING INFRASTRUCTURE COSTS.
Certification Standard
EN16034: the overarching standard for pedestrian and industrial fire/smoke doors & shutters. it mandates assessment against:
EN 1634-1: fire resistance test for doors, shutters, and operable fabric curtains (integrity, insulation)
EN 1364-2: fire resistance tests for non-loadbearing elements - part 2: ceilings (relevant for shutter boxes/cassettes).
EN 1363-1/2: general fire resistance test methods.
EN 13501-2: classification using test data from above
UL 10B / UL 10C: standard fire tests for door assemblies.
UL 263: standard for fire tests of building construction and materials (similar scope to ASTM 119).
Technical data
FIRE RATING | > or =3–4 HOURS (TESTED TO GB9978/EN 1634) | TYPES, APPLICATIONS & BENEFIT | |
BACKFACE TEMPERATURE | AVG. > or =380°C; MAX. SINGLE POINT > or = 180°C | ① DUAL-TRACK DUAL-CURTAIN | |
CURTAIN THICKNESS | 10–20 MM (MULTI-LAYER: CERAMIC FIBER + FIREPROOF CLOTH) | LARGE MALLS, ATRIUMS, INDUSTRIAL ZONES | |
OPERATION SPEED | 2.5–6.4 M/MIN (ELECTRIC); 4–5 M/MIN (GRAVITY FALL) | AIR-LAYER INSULATION; NO WATER SPRAY | |
AIR GAP (DUAL CURTAINS) | 300 MM (OPTIMIZES THERMAL INSULATION) | ② WATER-MIST STEEL SHUTTER | |
SOUND INSULATION | UP TO 42 DB REDUCTION | HIGH-HUMIDITY AREAS (E.G., PARKING GARAGES) | |
MOTOR POWER | 0.25–1.5 KW (AC/DC OPTIONS) | RAPID COOLING; SMOKE SUPPRESSION | |
MAX. DIMENSIONS | WIDTH: < or = 60 FT (18.3 M); HEIGHT: < or = 40 FT (12.2 M) | ③ FOLDABLE LIFT-TYPE | |
STRUCTURAL REQUIREMENTS | IRREGULAR OPENINGS (E.G., ESCALATORS, CURVED WALLS) | ||
WALL STRENGTH | MUST SUPPORT 300–500 KG LOADS; CONCRETE/BRICK WALLS RECOMMENDED. | SPACE-SAVING; COLUMN-FREE DESIGN | |
OPENING TOLERANCE | ≤5 MM DEVIATION (PLUMB/LEVEL) FOR SEAMLESS TRACK ALIGNMENT. | ④ INSULATED STEEL (FIRESTAR) | |
APPLICATION | BUILDING PROJECT, COMPANY, HOME, OFFICE, HOTEL, CHURCH, JUST ANYWHERE YOU WANT! | EXTREME CLIMATES (E.G., COLD STORAGE) | |
PACKAGE | INSIDE: PE PAPER | OUTSIDE: DOUBLE LAYERS CARTON BOX AND WOODEN PALLETS. | MINERAL WOOL CORE; U-VALUE < or = 0.8 W/M²K |
Doors Overviews